1. Product Introduction and Usage
DX-5012UV is a single component epoxy resin adhesive with a dual curing system, high thixotropy index, low shrinkage and repeatable shrinkage, high Tg and low CTE, good stability, and good adhesion to standard substrate configurations. DX-5012UV is designed specifically for active alignment applications in camera module assembly and laser radar module components. Main substrates include anodized aluminum, PBT, PPS, PCB, LCP, etc. First, cure with ultraviolet (UV) light, and then apply electronic materials by heating.
2. Material Characteristics Before Curing
Appearance | Translucent white |
Chemical composition of base material | Epoxy resin |
Viscosity(mPa·s@25℃)CP52、20R | 15000-18000 |
Thixotropic coefficient | 4.6 |
Density,g/cm | 1.5-1.6 |
3. Curing Time
Initial curing: 3-5 seconds @ 365nm UV, light intensity 200mW/cm ² -1000mW/cm ²
External heating curing: 50 minutes @ 85 ℃/30 minutes @ 100 ℃/20 minutes @ 120 ℃
*Water will accelerate its reaction and solidify when heated, and the speed and strength of solidification depend on the temperature and time of heating. The higher the temperature, the shorter the time required for solidification. It is necessary to adjust the heating temperature and time appropriately based on the heating efficiency of the heating equipment and the adhesive material to obtain the optimal process parameters.
4. Material Properties and Characteristics after Curing
Physical characteristics:
Main parameters | Typical values |
Thermal expansion coefficient(TMA℃)低于Tg | 33 |
Glass transition temperature Tg (TMA ℃) | 175 |
Curing shrinkage rate% | 1.27 |
Water absorption rate% | 0.19 |
Tensile modulus@25℃,MPa | 8000 |
Environmental standards | conform toROHS/HF/REACH |
Curing material sample curing UV (365 nanometers, 5s, 200mW/cm ²)+50 min@85 Sheet strength MPa at 25 ° C after ° C
3X3mm PBT and anodized aluminum | 24.8 |
3X3mm anodized aluminum and anodized aluminum | 22.1 |
3X3mmLCP and anodized aluminum | 10.1 |
3X3mm PCB and anodized aluminum | 10 |
3X3mm PPS and anodized aluminum | 8.9 |
5. Usage and Precautions
1、 At room temperature of 25 ℃ for 1-2 hours, wait for the glue to return to normal viscosity before use. Do not open the sealed packaging before this. It is not recommended to use it repeatedly for reheating.
2、 The substrate should be thoroughly cleaned to remove contaminants such as dust, salt, and oil that may cause poor adhesion or corrosion of the bonding components.
3、 The storage time at room temperature should be controlled within 24 hours.
4、 Excess uncured adhesive should be cleaned with solvents such as ketones and should not be poured into the original packaging.
Attention:
Please store away from children.
This product is recommended to be used in a well ventilated area.
If it accidentally gets on the skin, please wash it immediately with soapy water.
If it accidentally gets into the eyes, please wash with plenty of water first and then seek medical attention.
6. Packaging and Storage Conditions
30cc/piece or customized according to customer needs
The product is sealed and stored in a clean and dry place at -20 ℃.
Storage period: 6 months
Explanation: The information mentioned in this technical parameter, including recommendations for product use and application, is based on our company's knowledge and experience related to the product at the time of producing this technical parameter. We are not responsible for any results obtained by anyone using methods beyond our control. It is the user's responsibility to apply this product to the production methods mentioned in this technical specification and take the measures mentioned in this article to prevent possible losses and personal injuries during storage and use of the product. The product may have multiple uses and may change due to changes in usage and operating conditions beyond our control. Therefore, Dingxin New Materials is not responsible for whether the product is suitable for your company's production process, production conditions, expected use, and structure. We strongly recommend that your company conduct testing before producing the product to determine its suitability.
Unless otherwise expressly agreed, our company shall not be liable for the information in this technical specification or any other oral or written suggestions related to the product in question. The liability for personal injury or death caused by our company's negligence and the mandatory rules of the applicable product liability law shall not be included.